Refine

DNC Workwear Hi Vis FR & HRC2 Day/Night Rain Pants (3472)

SKU: 3472(DNC)
Manufacturer: DNC Workwear
  • Size chart
*
*
$146.87 incl GST
or 4 interest free payments of $36.72 with Afterpay logo Learn more

DNC Workwear Inherent FR PPE2 Basic Taped Pants (3471)

Fully seam sealed, HRC2 -- ATPV: 8+cal/cm2. Elastic waist with FR drawstring. 2 side storm flap inner pocket access with touch tape closure. Side storm flap SBS 5# Vislon sipper on gusset leg hem to easily slip on over boots. Hoop Pattern Bio-Motion "ANS UL=209 FR" Segmented FR reflective Tape (50 Washes) on lower legs

Attributes
  • SUN Protection UPF 50+ - DNC garments are tested for UPF (ultraviolet protection factor) in accordance with AS/NZS4399:1996. The level of protection varies depending on the fabric and colour of the garment. 15+ good protection, 30+ / 35+ very good protection, 40+ / 50+ excellent protection
  • Hi Vis - DNC Hi Vis fabric and reflective tape are manufactured to comply with the New Hi Vis standard Class F (AS/NZS1906.4:2010).
  • HiVis D/N Fabric & Design - DNC HiVis garments are manufactured to comply with New Hi Vis standard Class F AS/NZS1906.4:2010, Class DIN, AS/NZS 4602.1:2011 to meet the requirements of Hi­Vis Safety standards HiVis Fabric & Design of garments, for day and night use.
  • Waterproof & Breathable - Utilises the latest fabric technology. Not only are they waterproof, but also fully breathable.
  • Carbon grid Anti-static - The latest technology is used in the production of DNC Flame retardant + Carbon grid Anti-static 98% Polyester/PU, 2% Carbon, breathable waterproof fabric rain jacket, vest & pants. DNC cotton garments containing no metal buttons/zip are also classified under Anti-static garments. (Complies with EN ISO 14116:2008 for FR & BS EN1149-5:2008 for Anti-static).
  • ISO 14116:2015 (FR) - prescribes the performance criteria for material assemblies and protective clothing to minimise the risk of clothing igniting when exposed to small flames during short and intermittent contact, thereby minimising the potential hazard.
  • NENS09:2014 - Selected by Energy Networks Australia, use and maintenance of Personal Protective Equipment (PPE) used to protect people against electrical arc hazards within the Electricity Supply Industry. The recommended minimum ATPV for base garments is PPE (HRC 1) -- 4cal/cm2, and all opening/buttons/press studs/zippers are been covered by FR fabric.
  • PPE2 ATPV: 8+ caI/cm2 - Personal Protective Equipment (PPE) is an important line of defense in arc flash safety. NFPA 70E:2018 standard uses four categories of PPE, with each category including the minimum Arc Rating value for the required PPE. PPE 1: 4 cal/cm², PPE 2: 8 cal/cm², PPE 3: 25 cal/cm², PPE 4: 40 cal/cm²

DNC Workwear Inherent FR PPE2 Basic Taped Pants (3471)

Fully seam sealed, HRC2 -- ATPV: 8+cal/cm2. Elastic waist with FR drawstring. 2 side storm flap inner pocket access with touch tape closure. Side storm flap SBS 5# Vislon sipper on gusset leg hem to easily slip on over boots. Hoop Pattern Bio-Motion "ANS UL=209 FR" Segmented FR reflective Tape (50 Washes) on lower legs

Attributes
  • SUN Protection UPF 50+ - DNC garments are tested for UPF (ultraviolet protection factor) in accordance with AS/NZS4399:1996. The level of protection varies depending on the fabric and colour of the garment. 15+ good protection, 30+ / 35+ very good protection, 40+ / 50+ excellent protection
  • Hi Vis - DNC Hi Vis fabric and reflective tape are manufactured to comply with the New Hi Vis standard Class F (AS/NZS1906.4:2010).
  • HiVis D/N Fabric & Design - DNC HiVis garments are manufactured to comply with New Hi Vis standard Class F AS/NZS1906.4:2010, Class DIN, AS/NZS 4602.1:2011 to meet the requirements of Hi­Vis Safety standards HiVis Fabric & Design of garments, for day and night use.
  • Waterproof & Breathable - Utilises the latest fabric technology. Not only are they waterproof, but also fully breathable.
  • Carbon grid Anti-static - The latest technology is used in the production of DNC Flame retardant + Carbon grid Anti-static 98% Polyester/PU, 2% Carbon, breathable waterproof fabric rain jacket, vest & pants. DNC cotton garments containing no metal buttons/zip are also classified under Anti-static garments. (Complies with EN ISO 14116:2008 for FR & BS EN1149-5:2008 for Anti-static).
  • ISO 14116:2015 (FR) - prescribes the performance criteria for material assemblies and protective clothing to minimise the risk of clothing igniting when exposed to small flames during short and intermittent contact, thereby minimising the potential hazard.
  • NENS09:2014 - Selected by Energy Networks Australia, use and maintenance of Personal Protective Equipment (PPE) used to protect people against electrical arc hazards within the Electricity Supply Industry. The recommended minimum ATPV for base garments is PPE (HRC 1) -- 4cal/cm2, and all opening/buttons/press studs/zippers are been covered by FR fabric.
  • PPE2 ATPV: 8+ caI/cm2 - Personal Protective Equipment (PPE) is an important line of defense in arc flash safety. NFPA 70E:2018 standard uses four categories of PPE, with each category including the minimum Arc Rating value for the required PPE. PPE 1: 4 cal/cm², PPE 2: 8 cal/cm², PPE 3: 25 cal/cm², PPE 4: 40 cal/cm²
Products specifications
Fabric 280 GSM "3 layers bonded into 1" waterproof and breathable fabric, 99% Polyester and 1% anti-static Carbon outer laminated to 50% Modacrylic & 60% Cotton inner
Material Flame Retardant