Refine

Bisley Workwear Tencate Tecasafe® Plus 700 Taped Hi Vis FR Vented Shirt (BS8082T)

TENCATE TECASAFE® PLUS 700 TAPED HI VIS FR VENTED SHIRT LONG SLEEVE
SKU: BS8082T
Manufacturer: Bisley Workwear
Collection : Tecasafe®
  • Size chart
*
*
$166.32 incl GST
or 4 interest free payments of $41.58 with Afterpay logo Learn more

Bisley Workwear Tencate Tecasafe® Plus 700 Taped Hi Vis FR Vented Shirt (BS8082T)

  • Sto-nor 9801 FR Reflective taped hoop pattern
  • Action back panel ventilation with two openings and underarm ventilation
  • Two way radio loop or gas monitor loop on both sides
  • Two chest pockets with plastic press snap closure
  • Full gusset sleeve cuff with plastic snap closure
Attributes
  • Hi Visibility Material - This garment is developed to be seen in high-risk environments and protect you from workplace hazards. (AS/NZS 1906.4:2010)
  • Hi Vis Day or Night - Class D/N. Day/Night garments are developed to be worn both during the day and also at night. Hi Vis colours accompanied with retroreflective taping offer maximum reflection. (AS/NZS 4602.1:2011/Admdt2:2020)
  • UPF Rating 50 - The ultraviolet radiation transmitted through a fabric to the skin is measured. 50 offers excellent protection. (AS/NZS 4399:2017)
  • Industrial Strength - Reinforced stitching, bartacks, rivets and heavy-duty fabrics. It is developed for industrial environments or workplaces.
  • Cool Lightweight - We recognise the need to develop lightweight, breathable garments and have added mesh ventilation to crucial perspiration points on some garments.
  • Flame Resistant (FR) - Made with flame resistant, inherently non-flammable fabrics. These types of materials are designed to prevent the spread of fire and will not melt or drip when near a flame. (NFPA 2112:2018)
  • PPE 2 HRC 2 - Personal Protective Equipment (PPE) is an important line of defense in arc flash safety. NFPA 70E:2018 standard uses four categories of PPE, with each category including the minimum Arc Rating value for the required PPE. PPE 1: 4 cal/cm², PPE 2: 8 cal/cm², PPE 3: 25 cal/cm², PPE 4: 40 cal/cm²
  • ATPV Rating 8 - 9 - measurement of a material’s ability to protect a person from a burn due to exposure to incident energy resulting from an arc flash explosion. Units of cal/cm² (NFPA 70E:2018)
  • TECASAFE® PLUS - Engineered as a more comfortable and durable alternative to existing industrial FR fabrics, Tecasafe® Plus provides superior arc flash and flash fire protection. Featuring the enhanced comfort of Coolderm Technology, Tecasafe® Plus offers a proprietary fibre blend to keep you cooler when it's hot and drier when it's cool. Coolderm Technology keeps the wearer worry-free and very comfortable with active moisture wicking and excellent breathability. (NFPA:2112)

Bisley Workwear Tencate Tecasafe® Plus 700 Taped Hi Vis FR Vented Shirt (BS8082T)

  • Sto-nor 9801 FR Reflective taped hoop pattern
  • Action back panel ventilation with two openings and underarm ventilation
  • Two way radio loop or gas monitor loop on both sides
  • Two chest pockets with plastic press snap closure
  • Full gusset sleeve cuff with plastic snap closure
Attributes
  • Hi Visibility Material - This garment is developed to be seen in high-risk environments and protect you from workplace hazards. (AS/NZS 1906.4:2010)
  • Hi Vis Day or Night - Class D/N. Day/Night garments are developed to be worn both during the day and also at night. Hi Vis colours accompanied with retroreflective taping offer maximum reflection. (AS/NZS 4602.1:2011/Admdt2:2020)
  • UPF Rating 50 - The ultraviolet radiation transmitted through a fabric to the skin is measured. 50 offers excellent protection. (AS/NZS 4399:2017)
  • Industrial Strength - Reinforced stitching, bartacks, rivets and heavy-duty fabrics. It is developed for industrial environments or workplaces.
  • Cool Lightweight - We recognise the need to develop lightweight, breathable garments and have added mesh ventilation to crucial perspiration points on some garments.
  • Flame Resistant (FR) - Made with flame resistant, inherently non-flammable fabrics. These types of materials are designed to prevent the spread of fire and will not melt or drip when near a flame. (NFPA 2112:2018)
  • PPE 2 HRC 2 - Personal Protective Equipment (PPE) is an important line of defense in arc flash safety. NFPA 70E:2018 standard uses four categories of PPE, with each category including the minimum Arc Rating value for the required PPE. PPE 1: 4 cal/cm², PPE 2: 8 cal/cm², PPE 3: 25 cal/cm², PPE 4: 40 cal/cm²
  • ATPV Rating 8 - 9 - measurement of a material’s ability to protect a person from a burn due to exposure to incident energy resulting from an arc flash explosion. Units of cal/cm² (NFPA 70E:2018)
  • TECASAFE® PLUS - Engineered as a more comfortable and durable alternative to existing industrial FR fabrics, Tecasafe® Plus provides superior arc flash and flash fire protection. Featuring the enhanced comfort of Coolderm Technology, Tecasafe® Plus offers a proprietary fibre blend to keep you cooler when it's hot and drier when it's cool. Coolderm Technology keeps the wearer worry-free and very comfortable with active moisture wicking and excellent breathability. (NFPA:2112)
Products specifications
Fabric TENCATE TECASAFE® PLUS 700 FR MODACRYLIC LYOCELL ARAMID 238GSM TECASAFE® FR MESH 152GSM
Material Flame Retardant